Safety


Automation > Safety

Safety Interlock Switches

Safety Interlock Switches are a means of safeguarding that monitors the position of a guard or gate. You can use them to shut off power, control personnel access and prevent a machine from starting when the guard is open.

Tongue Interlock Switches

Tongue Interlock Switches allow the head of the switch to rotate, offering different options on how you can operate the switch and mount it on the guard. This flexibility offers the best fit for your applications. [More]

Trapped Key Switches

Trapped Key Interlock Switches can be configured to ensure that a predetermined sequence of events takes place or that hazards have been reduced before operators become exposed to them. [More]

Guard Locking Switches

Guard Locking Switches protect hazardous areas where a danger is not immediately removed after a stop request. On many machines, removing power to the motor or actuator will not immediately stop the dangerous motion. Typical applications are high inertia rotating machines, fast rotating machines, and machines where high pressure needs to be released from pneumatic valves. [More]

Non-Contact Interlock Switches

Non-Contact Interlock Switches help you protect personnel and equipment. At the same time, flexibility and productivity are points that you must also consider as you design your safety system. For non-contact interlocks, no physical contact (under normal conditions) takes place between the switch and actuator. [More]

Hinge Interlock Switches

Hinge Interlock Switches, when triggered, will close specific normally open (accessible) doors or guards. [More]

Safety Interlock Switch Accessories

Safety Interlock Switch Accessories include actuators, beacons and bulbs, conduit accessories, replacement covers, dust covers, and solenoid emergency overrides. [More]

Safety Programmable Logic Controllers

Safety PLC systems bring the benefits of traditional PLC systems to complex safety applications, replacing the hard-wired relay systems normally required to bring automated processes to a safe state. Safety PLCs allow standard and safety-related programs to reside in a single controller chassis, providing flexibility in programming as well as a familiar and easy-to-use environment for programmers. Our safety controller solutions provide open and integrated control that will help to ensure machine safety and protect your current control investments.

1752 SmartGuard 600 Controllers with Safety

Bulletin 1752 SmartGuard™ 600 safety controllers feature 16 safety-rated inputs, 8 safety-rated outputs, 4 pulse test sources and an optional EtherNet/IP™ port. Each controller also includes a DeviceNet™ connection to support both standard CIP and CIP safety. You can configure and program on EtherNet/IP, on DeviceNet or through the built-in USB port. These small, cost-effective intelligent controllers can perform safety interlocking between GuardLogix® or other SmartGuard safety controllers. [More]

GuardPLC Control System with Safety

GuardPLC™ Controller family offers superior speed in PLC throughput and network functionality. These controllers meet worldwide PLC standards and global standards for functional safety. This family is ideal for sensing speed, direction, zero-speed, temperature, pressure and flow applications. These controllers communicate on a Safe Ethernet communications network that is TÜV-certified for use in safety applications up to EN954 Category 4 and SIL 3. [More]

1756 GuardLogix Controllers with Safety

The 1756 GuardLogix® controller is a ControlLogix® controller that also provides safety control. As part of the Logix family, GuardLogix controllers use a common control engine with a common development environment to provide high performance multi-discipline control for SIL 3 safety applications. GuardLogix Safety PACs offer integrated safety, discrete, motion, drive and process control, as well as seamless connectivity to plant-wide information systems, all in the same controller. Use EtherNet/IP™ or ControlNet™ networks for safety interlocking between GuardLogix controllers. Connect field devices over EtherNet/IP or DeviceNet™ networks. [More]

1768 Compact GuardLogix Controllers with Safety

GuardLogix® controller is a ControlLogix® controller that also provides safety control. As part of the Logix family, Compact GuardLogix controllers use a common control engine with a common development environment to provide high performance multi-discipline control for SIL 3 safety applications. GuardLogix Safety PACs offer integrated safety, discrete, motion, drive and process control, as well as seamless connectivity to plant-wide information systems, all in the same controller. Use EtherNet/IP™ or ControlNet™ networks for safety interlocking between GuardLogix controllers. Connect field devices over EtherNet/IP or DeviceNet™ networks. [More]

Safety Relays & Timers

Safety Relays and Timers can be used in a variety of safety-related control applications to help protect personnel from unintended machine starts and loss of the safety function. Products include monitoring safety relays, timing control units, safety control relays, and single function and expansion relays. Specialty relays are also available for a wide-range of high-risk applications.

200 Series Modular Relays

The Guardmaster® MSR200 expandable modular relay system supports up to 22 diverse inputs including mats, light curtains and switches. This single-relay system allows safety control of larger, more complex manufacturing equipment. The microprocessor-based design offers diagnostic and communication functionality. This system can deliver output and error status over a fieldbus network to an HMI. Note that Guardmaster Safety Relays have been marketed by Rockwell Automation under the trade name "Minotaur" in the past. [More]

300 Series Configurable Relays

The Guardmaster® MSR300 family of expandable modular safety relays handles larger, more complicated safety systems by allowing connection of multiple input modules to a single base unit. It offers a logic configuration with multiple inputs and the control of multiple independent outputs. The system supports up to 20 diverse inputs and can control up to 3 zones, performing simple function block logic configurations through rotary switch settings as opposed to software configuration. Note that Guardmaster Safety Relays have been marketed by Rockwell Automation under the trade name "Minotaur" in the past. [More]

Timing Control Units

Timing control units energize and unlock guard-locking devices after a preset time delay expires. Generally used on machines that have a run-down cycle or do not stop immediately, these units can be incorporated anywhere in the safety-related controls system requiring a predictable on-delay. [More]

440R Power Supply Unit

The Guardmaster® power supply converts either 110V AC or 230V AC to 24V DC. It is intended to be used with an MSR5T or a Ferrotek noncontact interlock. Note that Guardmaster Safety Relays have been marketed by Rockwell Automation under the trade name "Minotaur" in the past. [More]

700S-CF Safety Control Relays

Bulletin 700S-CF Safety Control Relays provide mechanically or mirror contact performance, which are required in feedback circuits for safety applications. Bifurcated contacts are ideal for low energy feedback safety circuits where high contact reliability is required. [More]

700S Heavy-Duty Safety Control Relays

Bulletin 700S-P and 700S-PK Safety Control Relays are designed to meet worldwide safety standards. These relays have mechanically linked contacts and tamper-resistant covers. [More]

Expansion Relays

Safety Relay Expansion Units are designed to expand the number of outputs available when used with Guardmaster® Safety Relays and retain the same integrity as the base unit. [More]

Expansion Relays with Delayed Outputs

Expansion Relays with Delayed Outputs operate as extensions of a master safety relay. The outputs of the expansion relay mimic the outputs of the master. Delayed outputs are used in applications where power must be maintained for a fixed duration after an input signal is received. [More]

Single-Function Relays

The Guardmaster® MSR100 Single Function Safety Relays support a wide variety of input devices and output configurations. Ideal for relatively small safety applications and single zone control, MSR100 relays are compact packages with removable terminals. These relays are also available in electromechanical versions, or solid-state models for applications involving high cycle rates. Note that Guardmaster Safety Relays have been marketed by Rockwell Automation under the trade name "Minotaur" in the past. [More]

Single-Function Relays with Delayed Outputs

Safety Relays with Delayed Outputs are used in applications where power must be maintained for a fixed duration after an input signal is received. For example, driving a switch to maintain a guard door in the locked position for a fixed duration after a stop button is pressed. [More]

Specialty Relays

Specialty Relays and accessories are available for a wide-range of high-risk applications. [More]

Safety Sensors & Switches

Safety Switches and Sensors are designed and built to global standards for high reliability, stability, and quality. Safety sensor products include light curtains, safety edges and mats, and laser scanners. Safety switches include limit and interlock switches

Safety Edges

Safety Edges outperform the competition because of their innovative design. They use a combination of non-conductive rubber and flexible wire-cored conductive rubber bonded together so they keep bouncing back into shape even after repeated compressions. [More]

802T NEMA Safety Limit Switches

Bulletin 802T Direct Opening Action limit switches are used for safety applications per ISO 14119. These limit switches have the same mounting dimensions as other NEMA style limit switches. The rugged metal construction and plug-in body are designed for use in harsh industrial environments. Direct opening action assures that the normally closed contacts open when the limit switch is actuated. [More]

IEC Limit Switches

IEC Limit Switches have electrical interlocking of control circuits to the movement of the units actuator. Switch operation requires physical contact from the moving part of the machinery to the unit's actuator. These units are ideal for applications requiring sensing at either side of a sliding guard door. [More]

Safety Interlock Switches

Safety Interlock Switches are a means of safeguarding that monitors the position of a guard or gate. You can use them to shut off power, control personnel access and prevent a machine from starting when the guard is open. [More]

Safety Laser Scanners

Guardmaster® SafeZone™ Safety Laser Scanners are Type 3 opto-electronic devices that protect personnel or equipment by detecting them in its sensing field. Operating on the 'time of flight' principle, the scanners emit pulses of eye-safe infrared laser light over a 190-degree arc, then receive and process the light reflected off of intrusions in the sensing field to determine the position and distance to the object. When an object is detected, the scanners send a stop signal to the protected machine. [More]

Safety Light Curtains

Safety Light Curtains are opto-electronic presence sensing safety devices that detect the presence of an object in the light curtain’s sensing field. Most commonly used in machine guarding applications to detect the presence of a person’s finger, hand, limb or whole body. Also known as AOPDs (Active Opto-electronic Protective Devices), light curtains offer optimal safety. They are ideally suited for applications where personnel need frequent and easy access to a point of operation hazard. [More]

Safety Mats

MatGuard™ Systems consist of a number of interconnecting pressure-sensitive safety mats and a monitoring control unit that provide a system for area detection. We designed the mats from the 'ground up' to meet the arduous conditions found on the factory floor, and used well-tried components and techniques to be consistent with Category B and Category 1 requirements. [More]




Updated: 12/6/2011 3:06:00 PM - kkruger

5/18/2012 3:14:32 PM