Brand Name

Littelfuse®

Type

Current Limiting Medium Acting

Alternate Supplier #

Grainger - 486K24

Description

The unique design of Littelfuse® compact SLC series Class G fuses provide additional time delay over competitive products which increases system reliability. Compact Class G fuses were the first fuse series to approach midget fuse dimensions and meet NEC requirements for branch-circuit protection. The unique dimensions of SLC series Class G fuses prevents insertion of lower voltage fuses in Class G fuse holders. The fuse's varying length prevents insertion of higher ampere rated fuses in fuse holders designed for lower ampere ratings. Class CC fuses are replacing Class G fuses in many new designs. Class CC fuses' superior time delay plus higher voltage and interrupting ratings meet the needs of modern circuits. Littelfuse® introduction of POWR-PRO® CCMR series fuses, with ratings upto 60 A for providing branch circuit protection are accelerating this trend.
Littelfuse® POWR-GARD® Time Delay Fuse, Current Limiting Medium Acting, Series: SLC, Non-Indicating, 3 A, 600 VAC, 100 kA Interrupt, Class: G, Ferrule Terminal, Holder Mounting, Cartridge Body, 13/32 in Dia x 1-5/16 in L Body

Application

Branch Circuit Protection Applications

Standards

UL 248-5 | E81895 | CSA Certified | PROP65: This product can expose you to chemicals including nickel, which is known to the State of California to cause cancer

Features

  • Current limiting design reduces damage to equipment caused by heating and magnetic effects of short circuit currents
  • Medium time-delay allows fuses to be sized closer to actual equipment requirements no need to greatly oversize to withstand harmless equipment or system surges
  • Medium time-delay may reduce downtime caused by power surges or equipment demands
  • 100 kA at 600 VAC interrupting rating

Specifications

Amperage Rating:3 A
Body Size:13/32 in Dia x 1-5/16 in L
Body Type:Cartridge
Class:G
Country of Origin:MX
Indicating/Non-Indicating:Non-Indicating
Interrupt Rating:100 kA
Mounting Type:Holder
Series:SLC
Terminal Type:Ferrule
Voltage Rating:600 VAC