Mersen AMP-TRAP® 2000 SmartSpot® A6D30R Current Limiting Low Voltage North American Time Delay Power Fuse, 30 A, 600 VAC, 200 kA Interrupt, RK1 Class, Cylindrical Body
Manufacturer: Mersen
Manufacturer part number: A6D30R
Availability: Expected Leadtime 15 days
Estimated dates are contingent upon manufacturer stock.
CBT - Cincinnati CBT - Springboro CBT - Sidney
10 0 0
CRUSH BEARINGS & DRIVES - LEXINGTON CRUSH BEARINGS & DRIVES - LOUISVILLE
0 0
Loading...
$18.89

Product Details

Brand Name

Mersen

Type

Current Limiting Low Voltage North American Time Delay

Alternate Supplier #

Grainger - 4TCH1

Description

Amp-Trap® 2000 SmartSpot® time delay A6D-R fuses provide IEC type-2 "no damage" protection to existing mains, feeders and branch circuits serving motor and non-motor loads. A6D-R fuses will open fast enough under extreme fault conditions for maximum short circuit protection to prevent damage to motor starters, switches and other circuit components, yet also provide the time delay needed for motor inrush currents. A6D-R fuses can be used to replace obsolete 600 VAC class H, K or RK5 fuses already installed in the field.
Mersen AMP-TRAP® 2000 SmartSpot® Power Fuse, Current Limiting Low Voltage North American Time Delay, Series: A6D-R, Indicating, Rejection, 30 A, 600 VAC, 200 kA Interrupt, Class: RK1, Ferrule Terminal, Clip Mounting, Cylindrical Body, Dual Element, Fiberglass, 13/16 in Dia x 5 in L Body

Application

Motor, Safety Switches, Transformers, Disconnects, Control Panel and All General Purpose Circuits Applications

Standards

CSA C22.2 No. 248.12 | DC Listed | UL 248 | UL 248-12 File No. E2137

Features

  • Solid state SmartSpot® indicator
  • Time delay for motor starting and transformer inrush currents without nuisance opening
  • 300 kA interrupting rating, self certified (UL witnessed)
  • Extremely current limiting for low peak let-thru current
  • Easy 2-to-1 selectivity for prevention of nuisance shutdowns and "blackouts"
  • Rejection style design prevents replacement errors (when used with recommended fuse blocks)
  • High visibility orange label gives instant recognition
  • Reduced inventory by taking the place of class RK5, K and H fuses
  • Metal embossed date and catalog number for easier traceability and lasting identification
  • Fiberglass body provides dimensional stability in harsh industrial settings
  • High grade silica filler ensures fast arc quenching
  • Recommended for arc flash energy reduction
  • A6D-R fuses will open fast enough under extreme fault conditions for maximum short
  • Plated terminals
  • Arc flash mitigating
  • Tin-plated copper contact

Specifications

Amperage Rating:30 A
Body Size:13/16 in Dia x 5 in L
Body Type:Cylindrical
Class:RK1
Country of Origin:MX
Element:Dual
Indicating/Non-Indicating:Indicating
Interrupt Rating:200 kA
Material:Fiberglass
Mounting Type:Clip
Rejection/Non-Rejection:Rejection
Series:A6D-R
Terminal Type:Ferrule
Voltage Rating:600 VAC
Customers who bought this item also bought

TRS10R FER

MFG: Mersen
MFG#:TRS10R
Info:Mersen Tri-Onic® TRS10R Current Limiting Low Voltage Time Delay Fuse, 10 A, 600 VAC/VDC, 200/20 kA Interrupt, RK5 Class, Cylindrical Body

$ -.--

ATQR5 FER

MFG: Mersen
MFG#:ATQR5
Info:Mersen Amp-Trap® 2000 SmartSpot® ATQR5 Current Limiting Low Voltage North American Time Delay Power Fuse, 5 A, 600 VAC, 200 kA Interrupt, CC Class, Cylindrical Body

$ -.--

SUCTFB 207 20 IPC

MFG#:
Info:Stainless Insert Thermoplastic Housing 3

$ -.--