EWP4A9 APN

Product Details

Manufacturer:
Manufacturer part number:
EWP4A9
CBT Inventory
0
Vendor Inventory
Loading...
CBT - CINCINNATI
0
CBT - SPRINGBORO
0
CBT - SIDNEY
0
CBT - LEXINGTON
0
CBT - LOUISVILLE
0
Availability:
Expected Leadtime 7 days
Estimated dates are contingent upon manufacturer stock.
Price on Request

Description

Brand Name

Appleton®

Type

Explosionproof Factory Sealed

Description

Appleton® explosionproof, dust-ignitionproof, watertight, EWP Series circuit breaker panelboards provide protection and control of electrical equipment and circuits such as lighting and heat tracing in hazardous locations or in damp, wet or corrosive conditions. While the D2P Series is suitable for many of the most common hazardous areas, the EWP Series provides the extra protection needed for Class I, Division 1 areas.
Appleton® Circuit Breaker Panelboard, Explosionproof Factory Sealed, Series: EWP, 120/240 VAC, 250 A, 1 Pole, 10 kA Interrupt, 12 Circuits, QC/QPGF (GFI)/QPGFEP (EPD)/QC (HID) Breaker, 6 AWG to 250 kcmil Wire, Panel Mount, NEMA 3/3R/4/4X/5/7BCD/9EFG/12, Copper Free Aluminum Housing, 26 in H x 19.02 in W x 13.07 in D, Gray

Application

For protection and control of electrical equipment and circuits such as lighting and heat tracing in hazardous locations or in damp and wet or corrosive conditions

Standards

UL 877 | UL 1203 File No. E12108 | UL Listed for Class I, Div 1 and 2, Groups B, C, D, Class II, Div 1 and 2, Groups E, F, G, Class III

Features

  • Aluminum breaker actuators-spring loaded, corrosion resistant feature self locating design for actuating 1, 2, or 3 pole breakers in any sequence
  • Handles lock in either off or on position without interfering with tripping of breakers
  • Double door one for junction compartment and one for breaker compartment
  • Two O-ring gaskets on each breaker handle shaft to prevent entrance of water or corrosion
  • Hinges allow the doors to be lifted off
  • Breakers pre-wired to terminal block minimizes installation time
  • Insulated neutral lug provided as standard
  • Panelboards use standard Cutler-Hammer Quicklag® industrial circuit breakers
  • Provision for drains/breathers in both compartments
  • Factory sealed no external branch sealing fittings needed (except division 1 groups B and C )
  • Type THHN minimum size 10 AWG copper wire - 90 deg C (194 deg F) -used in panelboards, main lug feeder wires are crimped and installed in single conductor
  • Stainless steel captive, spring-out Quad-Lead® bolts for ease of access
  • Epoxy powder coated finish
  • Stainless steel hardware material
  • Rotary actuating handles may be individually padlocked
  • Both doors are fully gasketed to provide raintight fit for both compartments
  • Dust ignitionproof
  • Corrosion resistant

Includes

(2) Door, (2) O-Ring Gasket Stainless Steel Bolt

Specifications

Amperage Rating:250 A
Breaker Type:QC/QPGF (GFI)/QPGFEP (EPD)/QC (HID)
Color:Gray
Country of Origin:US
Dimensions:26 in H x 19.02 in W x 13.07 in D
Enclosure Type:NEMA 3/3R/4/4X/5/7BCD/9EFG/12
Housing Material:Copper Free Aluminum
Interrupt Rating:10 kA
Mounting Type:Panel
Number of Circuits:12
Number of Poles:1
Series:EWP
Voltage Rating:120/240 VAC
Wire Size:6 AWG to 250 kcmil