Chat Now

EYS116 APN

Appleton® UNILETS® EYS116 Dust-Ignitionproof Explosionproof Raintight Conduit Sealing Fitting With Removable Male Nipple, 1/2 in, For Use With IMC/Threaded Rigid Metallic Conduit, Grayloy-Iron, Triple Coated
Manufacturer: Appleton
Manufacturer part number: EYS116
Availability: Ships in 5-7 days.
Estimated dates are contingent upon manufacturer stock.
CBT - Cincinnati CBT - Springboro CBT - Sidney
0 0 0
CRUSH BEARINGS & DRIVES - LEXINGTON CRUSH BEARINGS & DRIVES - LOUISVILLE
0 0
Loading...
$31.44

Product Details

Brand Name

Appleton®

Type

Dust-Ignitionproof Explosionproof Raintight

Alternate Supplier #

Grainger - 10V057

Description

These Appleton® sealing fittings minimize the passage of gases and vapors and prevent the passage of flames from one portion of a conduit system to another. They prevent pressure piling within the conduit system and contain any explosion that occurs. These models in the EYS series provide a close turning radius and can be used for sealing vertical or horizontal conduit runs.
Appleton® UNILETS® Conduit Sealing Fitting, Dust-Ignitionproof Explosionproof Raintight, Series: EYS, 1/2 in, For Use With: IMC/Threaded Rigid Metallic Conduit, Grayloy-Iron, Gray, Triple Coated, 3.69 in L x 1.25 in W

Application

For prevent passage of gases, vapors or flames from one portion of conduit system to another

Standards

UL 886 | UL 1203 File No. E10444 | CSA C22.2 No. 30 | CSA 065181, Class I, Groups A, B, C, D, Class II, Groups E, F, G, Class III

Features

  • Smooth, rounded integral bushing in each hub to protect conductor insulation
  • Accurately tapped, tapered NPT threads for tight, rigid joints and ground continuity
  • Removable nipple in male sealing fitting may be used interchangeably in top or bottom hub
  • Large opening for damming and filling
  • Restrict any explosion to the sealed off enclosure
  • Required in Class I, Division 1 and 2 locations within 18 in of enclosures containing apparatus that may cause arcs, sparks or high temperatures
  • Required in Class I, Division 1 and 2 locations where 2 in or larger conduit enters enclosure, fitting housing terminals, splices or taps
  • Required in Class I, Division 1 and 2 locations at the boundary where conduit leaves classified location
  • Required in Class I, Division 1 and 2 locations where two or more enclosures are connected by 36 in or less conduit, seal must be located within 18 in of either enclosure
  • Required where cables which exceed rate of gas or vapor transmission permitted for seals are used in Class I, Division 2 locations
  • Tapered MNPT X tapered FNPT connection
  • 25% fill vertical and horizontal conduit sealing fittings for close turning radius
  • Chromate/epoxy powder coated/zinc electroplated finish

Specifications

Color:Gray
Country of Origin:MX
Dimensions:3.69 in L x 1.25 in W
Finish:Triple Coated
Material:Grayloy-Iron
Series:EYS
Size:1/2 in
Suitable For Use With:IMC/Threaded Rigid Metallic Conduit