Chat Now

MPDB66552 FER

Mersen MPDB66552 Intermediate Open Style Power Distribution Block, 1000 VAC/VDC, 350 A, 2 Poles, 14 to 2/0 AWG Wire, Polycarbonate
Manufacturer: Mersen
Manufacturer part number: MPDB66552
Availability: Expected Leadtime 30 days
Estimated dates are contingent upon manufacturer stock.
CBT - Cincinnati CBT - Springboro CBT - Sidney
2 0 0
CRUSH BEARINGS & DRIVES - LEXINGTON CRUSH BEARINGS & DRIVES - LOUISVILLE
0 0
Loading...
$293.92

Product Details

Brand Name

Mersen

Type

Intermediate Open Style

Description

The next generation power distribution block (PDB). Mersen power distribution blocks provide a safe and easy method of splicing cables, splitting primary power into secondary circuits and fulfilling requirements for fixed junction tap-off points. Unless noted otherwise, all blocks are UL and CSA approved while meeting spacing requirements for feeder and branch circuits in conjunction with UL 508 A and the national electric code. PDB options include single or dual conductor primary inputs and up to 30 secondary outputs. Specialty blocks are available allowing for up to 7 primary inputs.
Mersen Power Distribution Block, Intermediate Open Style, Series: MPDB, 1000 VAC/VDC, 350 A, 2 Pole, 2 Primary Connections/Pole, 15 Secondary Connection/Pole, 14 to 2/0 AWG Wire, 100 kA Short Circuit, Polycarbonate, TiN Coated, 3.57 in L x 4 in W x 2.62 in H Dimensions

Application

Cable Splicing, Splitting Primary Power into Secondary Circuits, Fixed Junction and Tap-Off Point Applications

Standards

CSA Class 6228 01 | RoHS Compliant | UL 1953/File No. E352417

Features

  • Adder poles can be stacked to form multi-pole units in the field without the use of tools, adder poles allow for customization of primary and secondary wire combinations
  • Aluminum connectors accept both AL or CU wire while copper connectors accept CU wire only and all 1-piece tin-plated
  • Insulators are virtually unbreakable, made of glass-filled polycarbonate, see-through hinged safety covers are optional and provide a greater deg of safety and shock resistance where required, hinged covers can be installed without tools
  • 1 in through air and 2 in over surface between uninsulated live parts of opposite polarity meets requirements for feeder and branch circuit applications of UL508A
  • Polycarbonate safety covers provide dead-front protection
  • Each cover has a test probe hole in the center for circuit checking
  • Tin-plated copper contact

Specifications

Amperage Rating:350 A
Country of Origin:MX
Dimensions:3.57 in L x 4 in W x 2.62 in H
Finish:TiN Coated
Material:Polycarbonate
Number of Poles:2
Primary Connections/Pole:2
Secondary Connection/Pole:15
Series:MPDB
Short Circuit Current Rating:100 kA
Voltage Rating:1000 VAC/VDC
Wire Size:14 to 2/0 AWG